18 0749_18 0748_282022_024948.mp4
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
4 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
4 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR CORRODED & MISSING
8 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO - MISSING REBAR
19.4 ft. - Surface Missing Wall, from 03 to 04 o'clock, within 8 inches of joint: NO - SOIL VISIBLE
19.4 ft. - General Photograph - POSSIBLE SOIL
33.9 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO - MISSING REBAR
38.8 ft. - Surface Missing Wall, from 03 to 04 o'clock, within 8 inches of joint: NO - SOIL VISIBLE
177.9 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR CORRODED MISSING
| Distance | Code | Observation |
|---|---|---|
| 33.9 | SRC | MISSING REBAR |
| 38.8 | SMW | SOIL VISIBLE |
| 19.4 | SMW | SOIL VISIBLE |
| 8 | SRC | MISSING REBAR |
| 0 | MWL | — |
| 19.4 | MGP | POSSIBLE SOIL |
| 2 | SSS | BLISTERING PEELING CONCRETE |
| 400.2 | SAM | SEVERE AGG |
| 4 | SAM | SEVERE AGG |
| 0 | AMH | 3:35AM |
| 400.2 | SSS | BLISTERINMG PEELING CONCRETE |
| 4 | SRC | LONG CIRCUM REBAR CORRODED & MISSING |
| 177.9 | SRC | LONG CIRCUM REBAR CORRODED MISSING |
| 376.3 | SRC | LONG CIRCUM REBAR CORRODED MISSING |
| 0 | MWM | — |
| 404.2 | AMH | 4:35AM |