05 1895_05 1894_242022_092327.mp4
8.8 ft. - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: YES, 4" - ROOTS, 15%
9.4 ft. - Roots Ball Lateral, at 11 o'clock, 95 %, within 8 inches of joint: YES
64.8 ft. - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 4"
70.2 ft. - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 4" - 5% ROOTS
84.6 ft. - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4" - LINER
| Distance | Code | Observation |
|---|---|---|
| 8.8 | TFD | ROOTS, 15% |
| 84.6 | MSA | PASSED 50 FT PROPERTY MARK, LATERAL INSPECTION ONLY |
| 84.6 | TFA | LINER |
| 70.2 | TFA | 5% ROOTS |
| 9.4 | RBL | — |
| 0 | AMH | 09:22AM |
| -0.1 | MWM | — |
| 64.8 | TFC | — |
| 0 | MWL | — |