Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 20, 2021, 05:52 PM
  • 22 0755_22 0754_12202021_101234.mp4

Date
12/20/2021
W/O
926452
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00821
PipeID
P17112
Time
9:52 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9150
Sewer Name
22 PUDDINGSTONE TRUNK, SECTS 1&2
City
LA VERNE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
23
Purpose
Routine Assessment
Project
RFIR_WO_926452_TV22097_DEC2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0755
Downstream MH
22 0754
Dir. of Survey
Downstream
Length Surveyed
270.2 ft.
Total Length
270.2 ft.
Structural Index
3
Structural Quick
3A00
Structural Rating
33
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
33
Pipe schematic from manhole 22 0755 to 22 0754
MH: 22 0755MH: 22 0754downstream0 ft. MGO - General Observation - PIPE IS VCP0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 07550 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK18.6 ft. MGO - General Observation - MAG COATING THROUGHOUT35.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"86.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"105.3 ft. CM - Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES112.2 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES138.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"171.2 ft. CM - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES189.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"199 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: NO233.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start243.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"268.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish270.2 ft. AMH - Downstream Manhole, Survey Ends - 22 0754

Observation photos (7)

  • General Observation - PIPE IS VCP

    0 ft. - General Observation - PIPE IS VCP

  • General Observation - MAG COATING THROUGHOUT

    18.6 ft. - General Observation - MAG COATING THROUGHOUT

  • Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES

    105.3 ft. - Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    112.2 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

    171.2 ft. - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: NO

    199 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: NO

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    233.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (18)

DistanceCodeObservation
18.6MGOMAG COATING THROUGHOUT
0MGOPIPE IS VCP
243.4TF
0MWL
268.9CM
233.7CM
35.8TFC
0AMH22 0755
0MWM
171.2CM
270.2AMH22 0754
112.2CM
86.3TFC
105.3CM
0MGOCONNECTION AT MH 9 O'CLOCK
189.1TFC
199CM
138.1TFC

Properties (7)

additional_info
630098122021062
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-12-20T09:52:31-08:00
documentation
PRO PIPE
is_lateral_inspection
false