Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 29, 2021, 10:40 AM
  • A 0906_A 0905_11292021_025326.mp4

Date
11/29/2021
W/O
921697
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00318
PipeID
P08000
Time
2:40 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9549
Sewer Name
A JOA-1A FLORENCE AVENUE INTERCEPTOR
City
NORWALK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
25
Purpose
Routine Assessment
Project
WO_921697_TV18067_NOV2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
54 in.
Upstream MH
A 0906
Downstream MH
A 0905
Dir. of Survey
Downstream
Length Surveyed
593.8 ft.
Total Length
593.8 ft.
Structural Index
2
Structural Quick
2200
Structural Rating
4
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole A 0906 to A 0905
MH: A 0906MH: A 0905downstream0 ft. AMH - Upstream Manhole, Survey Begins - A 09060 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start2.1 ft. MGO - General Observation - MAG COAT593 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish593.8 ft. AMH - Downstream Manhole, Survey Ends - A 0905

Observations (7)

DistanceCodeObservation
593SSS
2SSS
0AMHA 0906
2.1MGOMAG COAT
0MWM
593.8AMHA 0905
0MWL

Properties (8)

additional_info
630074112921001
custom_field_three
SPALLING/SURFACE AGGREGATE
custom_field_two
3
customer
1
datetime
2021-11-29T02:40:39-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
31604