Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 19, 2022, 09:19 PM
  • 05 1533_05 2668_01192022_132620.mp4

Date
01/19/2022
W/O
926630
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00495
PipeID
P26296
Time
1:19 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9709
Sewer Name
05 NORTH TORRANCE TRUNK
City
TORRANCE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
26
Purpose
Routine Assessment
Project
WO_926630_TV05055_DEC2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
05 2668
Downstream MH
05 1533
Dir. of Survey
Upstream
Length Surveyed
3.4 ft.
Total Length
3.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
5131
O&M Rating
8
Overall Index
4
Overall Quick
Overall Rating
8
Pipe schematic from manhole 05 2668 to 05 1533
MH: 05 2668MH: 05 1533upstream0 ft. MSA - Survey Abandoned - DUE TO DEBRIS1.2 ft. OBZ - Obstacles Other, 15 %of cross sectional area, at 06 o'clock - UNDER FLOW1.4 ft. MGO - General Observation - PIPE IS VCP3.4 ft. MWM - Water Mark, 100 %of cross sectional area3.4 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK3.4 ft. MWL - Water Level, 35 %of cross sectional area3.4 ft. AMH - Downstream Manhole, Survey Begins - 05 2668

Observation photos (3)

  • General Observation - PIPE IS VCP

    2 ft. - General Observation - PIPE IS VCP

  • Obstacles Other, 15 %of cross sectional area, at 06 o'clock - UNDER FLOW

    2.2 ft. - Obstacles Other, 15 %of cross sectional area, at 06 o'clock - UNDER FLOW

  • Survey Abandoned - DUE TO DEBRIS

    3.4 ft. - Survey Abandoned - DUE TO DEBRIS

Observations (7)

DistanceCodeObservation
3.4MSADUE TO DEBRIS
0MWM
0MGOCONNECTION AT MH 3 O'CLOCK
0MWL
0AMH05 2668
2.2OBZUNDER FLOW
2MGOPIPE IS VCP

Properties (7)

additional_info
630074011922061
custom_field_three
, HEAVY STEAM
custom_field_two
5
customer
1
datetime
2022-01-19T13:19:22-08:00
documentation
PRO PIPE
is_lateral_inspection
false