- Date
- 01/19/2022
- W/O
- 926630
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00495
- PipeID
- P06758
- Time
- 9:00 AM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9709
- Sewer Name
- 05 NORTH TORRANCE TRUNK
- City
- TORRANCE
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 26
- Purpose
- Routine Assessment
- Project
- WO_926630_TV05055_DEC2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 24 in.
- Width
- 10 in.
- Upstream MH
- 05 1536
- Downstream MH
- 05 1535
- Dir. of Survey
- Downstream
- Length Surveyed
- 361.3 ft.
- Total Length
- 361.3 ft.
- Structural Index
- 2
- Structural Quick
- 2100
- Structural Rating
- 2
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 2
Pipe schematic from manhole 05 1536 to 05 1535 Observation photos (3)

3.2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

3.2 ft. - General Observation - MAG COAT

361.3 ft. - Survey Abandoned - WHEELS UNABLE TO GET TRACTION