Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 21, 2021, 07:18 AM
  • 01 0530_01 0529_12202021_232955.mp4

Date
12/20/2021
W/O
926527
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00206
PipeID
P01017
Time
11:18 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9644
Sewer Name
01 CROCKETT BOULEVARD-GLEN AVENUE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_926527_TV01239_DEC2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0530
Downstream MH
01 0529
Dir. of Survey
Downstream
Length Surveyed
167.2 ft.
Total Length
167.2 ft.
Structural Index
4
Structural Quick
4E00
Structural Rating
112
O&M Index
2
O&M Quick
4131
O&M Rating
73
Overall Index
3
Overall Quick
Overall Rating
185
Pipe schematic from manhole 01 0530 to 01 0529
MH: 01 0530MH: 01 0529downstream0 ft. MGO - General Observation - CONNECTION AT MH 6 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 01 05300 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start5 ft. DAGS - Deposits Attached Grease, 15 %of cross sectional area, from 03 to 05 o'clock, , within 8 inches of joint: YES - GREASE DEPOSITS23.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start73.9 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"76.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"125.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"127.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"165.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish165.6 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish167.2 ft. AMH - Downstream Manhole, Survey Ends - 01 0529167.2 ft. MGO - General Observation - COCKROACHES IN MH

Observation photos (3)

  • Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    23.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MH

    167.2 ft. - General Observation - COCKROACHES IN MH

Observations (15)

DistanceCodeObservation
0MGOCONNECTION AT MH 6 O'CLOCK
23.4FM
5DAGSGREASE DEPOSITS
2DAGS
0AMH01 0530
167.2AMH01 0529
76.6TFC
0MWL
127.6TFC
165.6FM
0MWM
165.6DAGS
73.9TFC
167.2MGOCOCKROACHES IN MH
125.1TFC

Properties (7)

additional_info
630138122021201
custom_field_three
MULTIPLE FRACTURES
custom_field_two
2
customer
1
datetime
2021-12-20T23:18:56-08:00
documentation
PRO PIPE
is_lateral_inspection
false