- Date
- 12/21/2021
- W/O
- 926527
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00206
- PipeID
- P01006
- Time
- 1:01 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9644
- Sewer Name
- 01 CROCKETT BOULEVARD-GLEN AVENUE TRUNK
- City
- LOS ANGELES
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 10
- Purpose
- Routine Assessment
- Project
- RFIR_WO_926527_TV01239_DEC2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 01 0521
- Downstream MH
- 01 0520A
- Dir. of Survey
- Downstream
- Length Surveyed
- 161.5 ft.
- Total Length
- 161.5 ft.
- Structural Index
- 3
- Structural Quick
- 3200
- Structural Rating
- 6
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 8
Pipe schematic from manhole 01 0521 to 01 0520A Observation photos (4)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

4.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

23.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

161.5 ft. - General Observation - COCKROACHES IN MH