Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 16, 2021, 11:40 AM
  • H 1280_H 1329_11162021_034737.mp4

Date
11/16/2021
W/O
921627
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z01184
PipeID
P25889
Time
3:40 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9500
Sewer Name
H JOINT OUTFALL H - UNIT 8L RELIEF
City
AZUSA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
11
Purpose
Routine Assessment
Project
WO_921627_TV22099_NOV2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
H 1329
Downstream MH
H 1280
Dir. of Survey
Upstream
Length Surveyed
5.9 ft.
Total Length
5.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
4122
O&M Rating
8
Overall Index
3
Overall Quick
Overall Rating
8
Pipe schematic from manhole H 1329 to H 1280
MH: H 1329MH: H 1280upstream0 ft. LU - Alignment Up, 30 %0 ft. MSA - Survey Abandoned - DUE TO ALIGNMENT CHANGE0 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 12 to 12 o'clock, , within 8 inches of joint: YES, Finish3.9 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 12 to 12 o'clock, , within 8 inches of joint: YES, Start5.9 ft. MGO - General Observation - ACTIVE CONNECTIONS IN MH AT BOTH 6 AND 9 O' CLOCK5.9 ft. MWL - Water Level, 5 %of cross sectional area5.9 ft. AMH - Downstream Manhole, Survey Begins - H 13295.9 ft. MWM - Water Mark, 5 %of cross sectional area

Observation photos (2)

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 12 to 12 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 12 to 12 o'clock, , within 8 inches of joint: YES, Start

  • Survey Abandoned - DUE TO ALIGNMENT CHANGE

    5.9 ft. - Survey Abandoned - DUE TO ALIGNMENT CHANGE

Observations (8)

DistanceCodeObservation
0MGOACTIVE CONNECTIONS IN MH AT BOTH 6 AND 9 O' CLOCK
0MWL
2DAE
0AMHH 1329
5.9LU
5.9MSADUE TO ALIGNMENT CHANGE
5.9DAE
0MWM

Properties (8)

additional_info
630069111521201
custom_field_three
LIGHT ENCRUSTATION
custom_field_two
4
customer
1
datetime
2021-11-16T03:40:49-08:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
39562