Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 3, 2021, 07:40 AM
  • 02 1440_02 1439_11022021_235442.mp4

Date
11/03/2021
W/O
921615
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00307
PipeID
P04679
Time
12:40 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9523
Sewer Name
02 TRACT #5445 TRUNK
City
COMMERCE
Loc. details
Sidewalk
Location Code
F
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_921615_TV02302_NOV2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 1440
Downstream MH
02 1439
Dir. of Survey
Downstream
Length Surveyed
358.6 ft.
Total Length
358.6 ft.
Structural Index
4
Structural Quick
4H3C
Structural Rating
260
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
4
Overall Quick
Overall Rating
262
Pipe schematic from manhole 02 1440 to 02 1439
MH: 02 1440MH: 02 1439downstream0 ft. MGO - General Observation - HEAVY STEAM0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 14400 ft. MWL - Water Level, 5 %of cross sectional area3.6 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES18.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start32.3 ft. FC - Fracture Circumferential, from 07 to 10 o'clock, within 8 inches of joint: YES48.3 ft. FC - Fracture Circumferential, from 07 to 10 o'clock, within 8 inches of joint: YES114.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES124.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start124.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish139.2 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"141.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"213.1 ft. TSI - Tap Saddle Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1"252.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"265.6 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"358.5 ft. MGO - General Observation - BROKEN SHELF AT 9 O'CLOCK IN D/S MH358.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish358.6 ft. AMH - Downstream Manhole, Survey Ends - 02 1439

Observation photos (10)

  • Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    3.6 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    18.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Circumferential, from 07 to 10 o'clock, within 8 inches of joint: YES

    32.3 ft. - Fracture Circumferential, from 07 to 10 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 07 to 10 o'clock, within 8 inches of joint: YES

    48.3 ft. - Fracture Circumferential, from 07 to 10 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    114.6 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    124.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    139.2 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Saddle Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

    213.1 ft. - Tap Saddle Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    265.6 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • General Observation - BROKEN SHELF AT 9 O'CLOCK IN D/S MH

    358.5 ft. - General Observation - BROKEN SHELF AT 9 O'CLOCK IN D/S MH

Observations (19)

DistanceCodeObservation
3.6CL
0MGOHEAVY STEAM
265.6TB
0MWM
358.5MGOBROKEN SHELF AT 9 O'CLOCK IN D/S MH
0AMH02 1440
18.8CM
32.3FC
213.1TSI
124.5FM
358.6FM
358.6AMH02 1439
141.2TFC
139.2TB
48.3FC
114.6FL
0MWL
252.9TFC
124.5CM

Properties (7)

additional_info
630074110221203
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-11-03T00:40:02-07:00
documentation
PROPIPE
is_lateral_inspection
false