- Date
- 12/02/2021
- W/O
- 926976
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z01090
- PipeID
- P24555
- Time
- 8:52 AM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9289
- Sewer Name
- 29 ALAMITOS PUMPING PLANT SEWER
- City
- SIGNAL HILL
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 29
- Page No.
- 04
- Purpose
- Routine Assessment
- Project
- RFIR_WO_926976_TV29057_DEC2021
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 8 in.
- Width
- 8 in.
- Upstream MH
- 29 0506
- Downstream MH
- 29 0505
- Dir. of Survey
- Downstream
- Length Surveyed
- 159.7 ft.
- Total Length
- 159.7 ft.
- Structural Index
- 3
- Structural Quick
- 423I
- Structural Rating
- 223
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 223
Pipe schematic from manhole 29 0506 to 29 0505 Observation photos (3)

2.5 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

10.1 ft. - Fracture Spiral, from 08 to 12 o'clock, within 8 inches of joint: YES

143.8 ft. - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start