- Date
- 12/03/2021
- W/O
- 926976
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z01090
- PipeID
- P24493
- Time
- 9:22 AM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9290
- Sewer Name
- 29 ALAMITOS PUMPING PLANT SEWER
- City
- SIGNAL HILL
- Loc. details
- Parking Lot
- Location Code
- G
- Use of Sewer
- Sanitary Sewer
- District
- District 29
- Page No.
- 04
- Purpose
- Routine Assessment
- Project
- RFIR_WO_926976_TV29057_DEC2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Width
- 8 in.
- Upstream MH
- 29 0452
- Downstream MH
- 29 0453
- Dir. of Survey
- Upstream
- Length Surveyed
- 306.5 ft.
- Total Length
- 306.5 ft.
- Structural Index
- 2
- Structural Quick
- 3B2N
- Structural Rating
- 203
- O&M Index
- 2
- O&M Quick
- 2K00
- O&M Rating
- 122
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 325
Pipe schematic from manhole 29 0452 to 29 0453 Observation photos (5)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

50 ft. - Water Level, Sag in pipe, 10 %of cross sectional area, Start

106 ft. - Water Level, Sag in pipe, 15 %of cross sectional area, Start

204.8 ft. - Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

204.8 ft. - Material Change, Cast Iron