- Date
- 01/25/2022
- W/O
- 0931953
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00652
- PipeID
- P13314
- Time
- 4:34 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H2090R
- Sewer Name
- 16 CHAPEL AVENUE TRUNK, SECTION 1
- City
- PASADENA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 17
- Purpose
- Maintenance Related
- Project
- 20220125MDM_CHAPEL_AVENUE_TRUNK_SECTION_1
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Upstream MH
- 16 0272
- Downstream MH
- 16 0266
- Dir. of Survey
- Downstream
- Length Surveyed
- 234.2 ft.
- Total Length
- 234.2 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 1
- O&M Quick
- 311A
- O&M Rating
- 13
- Overall Index
- 1
- Overall Quick
- —
- Overall Rating
- 13
Pipe schematic from manhole 16 0272 to 16 0266