- Date
- 11/15/2021
- W/O
- 916676
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00710
- PipeID
- P14961
- Time
- 11:09 AM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9281
- Sewer Name
- 18 SO WHITTIER OUTFALL RLF TR, SECTS 2E&2F
- City
- WHITTIER
- Loc. details
- Other
- Location Code
- Z
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 26
- Purpose
- Routine Assessment
- Project
- WO_916676_TV18111_OCT2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 24 in.
- Width
- 24 in.
- Upstream MH
- 18 1189
- Downstream MH
- 18 1188
- Dir. of Survey
- Downstream
- Length Surveyed
- 410.5 ft.
- Total Length
- 410.5 ft.
- Structural Index
- 4
- Structural Quick
- 4333
- Structural Rating
- 21
- O&M Index
- 1
- O&M Quick
- 1800
- O&M Rating
- 8
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 29
Pipe schematic from manhole 18 1189 to 18 1188 Observation photos (6)

7.5 ft. - Fracture Spiral, from 07 to 11 o'clock, within 8 inches of joint: YES

12.3 ft. - Fracture Spiral, from 07 to 08 o'clock, within 8 inches of joint: YES

14.4 ft. - Fracture Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES

36 ft. - Fracture Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES

39.4 ft. - Fracture Multiple, from 09 to 11 o'clock, within 8 inches of joint: YES

50.8 ft. - Fracture Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES