Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 15, 2021, 05:48 AM
  • 05 0933_05 0932_12142021_215923.mp4

Date
12/14/2021
W/O
926578
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00547
PipeID
P06165
Time
9:48 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9566
Sewer Name
05 120TH STREET EXTENSION TRUNK
City
HAWTHRONE
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_926578_TV05372_DEC2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 0933
Downstream MH
05 0932
Dir. of Survey
Downstream
Length Surveyed
232.5 ft.
Total Length
232.5 ft.
Structural Index
3
Structural Quick
3H2H
Structural Rating
228
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
228
Pipe schematic from manhole 05 0933 to 05 0932
MH: 05 0933MH: 05 0932downstream0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 09332.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start7.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start231.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish232.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish232.5 ft. AMH - Downstream Manhole, Survey Ends - 05 0932232.5 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK CAPPED232.5 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK CAPPED

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    7.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
232.4SAV
7.3SSS
0MGOCONNECTION AT THE MH 9 OC'LOCK
2.1SAV
231.8SSS
0MWM
0MWL
232.5AMH05 0932
232.5MGOCONNECTION AT THE MH 3 OC'LOCK CAPPED
0AMH05 0933
232.5MGOCONNECTION AT THE MH 9 OC'LOCK CAPPED

Properties (7)

additional_info
630074121421201
custom_field_three
SURFACE SPALLING AGGREGATE VISIBLE
custom_field_two
2
customer
1
datetime
2021-12-14T21:48:01-08:00
documentation
PROPIPE
is_lateral_inspection
false