Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 7, 2021, 10:24 AM
  • 18 0977_18 1228_12072021_022327.mp4

Date
12/07/2021
W/O
926979
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z01143
PipeID
P25609
Time
2:24 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9616
Sewer Name
18 WORSHAM CREEK REPLACEMENT TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
11
Purpose
Routine Assessment
Project
WO_926979_TV18077_DEC2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
18 1228
Downstream MH
18 0977
Dir. of Survey
Upstream
Length Surveyed
10.2 ft.
Total Length
10.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 18 1228 to 18 0977
MH: 18 1228MH: 18 0977upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 09771.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish5.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"8.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start10.2 ft. MWL - Water Level, 5 %of cross sectional area10.2 ft. AMH - Downstream Manhole, Survey Begins - 18 122810.2 ft. MWM - Water Mark, 15 %of cross sectional area

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
2DAGS
9DAGS
0MWL
0AMH18 1228
10.2AMH18 0977
4.6TFA
0MWM

Properties (8)

additional_info
630138120621203
custom_field_three
LIGHT GREASE
custom_field_two
4
customer
1
datetime
2021-12-07T02:24:34-08:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
38658