- Date
- 12/13/2021
- W/O
- 926960
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00683
- PipeID
- P14125
- Time
- 9:49 PM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9629
- Sewer Name
- 18 LA MIRADA TRUNK, SECTS 1&2
- City
- SANTA FE SPRINGS
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 31
- Purpose
- Routine Assessment
- Project
- RFIR_WO_926960_TV18144_DEC2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 18 0296
- Downstream MH
- 18 0295
- Dir. of Survey
- Downstream
- Length Surveyed
- 349.1 ft.
- Total Length
- 349.1 ft.
- Structural Index
- 3
- Structural Quick
- 4123
- Structural Rating
- 10
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 10
Pipe schematic from manhole 18 0296 to 18 0295 Observation photos (4)

22.7 ft. - Fracture Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES

101.2 ft. - Crack Spiral, from 10 to 02 o'clock, within 8 inches of joint: NO

263.6 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

313.7 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: NO