2 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR CORRODED & MISSING & MISSING
2 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
12 ft. - Surface Reinforcement Corroded, from 11 to 02 o'clock, within 8 inches of joint: YES, Start - CORROSION BEYOUND REBAR
12 ft. - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - POSSIBLE SOIL
25.6 ft. - Surface Missing Wall, from 12 to 02 o'clock, within 8 inches of joint: NO - POSSIBLE SOIL VISIBLE
36.7 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - MISSING REBAR
52.6 ft. - Surface Missing Wall, from 01 to 02 o'clock, within 8 inches of joint: NO - SOIL VISIBLE
57.6 ft. - General Photograph - SOIL VISIBLE
57.6 ft. - Surface Missing Wall, from 01 to 02 o'clock, within 8 inches of joint: YES, Start - SOIL VISIBLE
60.6 ft. - Surface Missing Wall, from 10 to 11 o'clock, within 8 inches of joint: NO - SOIL VISIBLE
76 ft. - Surface Missing Wall, from 01 to 02 o'clock, within 8 inches of joint: YES, Finish - SOIL VISIBLE
79.4 ft. - Surface Missing Wall, from 01 to 02 o'clock, within 8 inches of joint: YES, Start - SOIL VISIBLE
95 ft. - Surface Missing Wall, from 01 to 02 o'clock, within 8 inches of joint: NO - SOIL VISIBLE
125.2 ft. - Surface Missing Wall, from 01 to 02 o'clock, within 8 inches of joint: NO - SOIL VISIBLE
144 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CORROSION BEYOUND REBAR
189 ft. - Surface Missing Wall, from 01 to 02 o'clock, within 8 inches of joint: NO - SOIL VISIBLE
191 ft. - Surface Missing Wall, from 01 to 02 o'clock, within 8 inches of joint: NO - SOIL VISIBLE
196.4 ft. - Surface Missing Wall, from 01 to 02 o'clock, within 8 inches of joint: YES, Start - SOIL VISIBLE SPORATIC
| Distance | Code | Observation |
|---|---|---|
| 144 | SRC | CORROSION BEYOUND REBAR |
| 350.2 | SRC | LONG CIRCUM REBAR CORRODED & MISSING |
| 57.6 | MGP | SOIL VISIBLE |
| 351 | MSA | LACK OF FLOW TO FLOAT CAMERA |
| 2 | SSS | BLISTERING PEELING CONCRETE |
| 101.4 | SMW | — |
| 0 | MGO | Conn. @ Mh, 3 O' Clock. Active LARGE INCOMING LINE |
| 191 | SMW | SOIL VISIBLE |
| 350.2 | SRC | CORROSION BEYOUND REBAR |
| 25.6 | SMW | POSSIBLE SOIL VISIBLE |
| 12 | SRC | CORROSION BEYOUND REBAR |
| 0 | AMH | 12:55AM |
| 242.7 | SMW | SOIL VISIBLE |
| 2 | SRC | LONG CIRCUM REBAR CORRODED & MISSING & MISSING |
| 242.7 | MWL | — |
| 350.2 | SRC | CORROSION BEYOUND REBAR |
| 79.4 | SMW | SOIL VISIBLE |
| 52.6 | SMW | SOIL VISIBLE |
| 57.6 | SMW | SOIL VISIBLE |
| 196.4 | SMW | SOIL VISIBLE SPORATIC |
| 0 | MWM | — |
| 60.6 | SMW | SOIL VISIBLE |
| 189 | SMW | SOIL VISIBLE |
| 350.2 | SSS | BLISTEERING PEELING CONCRETE |
| 12 | SMW | POSSIBLE SOIL |
| 36.7 | SRC | MISSING REBAR |
| 0 | MWM | — |
| 76 | SMW | SOIL VISIBLE |
| 0 | MWL | — |
| 125.2 | SMW | SOIL VISIBLE |
| 2 | SAM | SEVERE AGG |
| 350.2 | SAM | SEVERE AGG |
| 95 | SMW | SOIL VISIBLE |