Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 3, 2022, 09:27 AM
  • J 0329_J 0328_132022_015906.mp4

Date
01/03/2022
W/O
0933575
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00059
PipeID
P11573
Time
1:27 AM
Certificate
U-1014-06220543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
H2066
Sewer Name
J JOINT OUTFALL J - UNIT 1G
City
PALO VERDES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 30
Page No.
10
Purpose
Maintenance Related
Project
20220103MDM_JOINT_OUTFALL_J_UNIT_1G
Material
Vitrified Clay Pipe
Shape
Circular
Height
9.600000381469727 in.
Upstream MH
J 0328
Downstream MH
J 0329
Dir. of Survey
Upstream
Length Surveyed
326.6 ft.
Total Length
326.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole J 0328 to J 0329
MH: J 0328MH: J 0329upstream0 ft. AMH - Upstream Manhole, Survey Ends - 4:35AM52.1 ft. MGO - General Observation - 9.5' VCP-PVCP326.6 ft. AMH - Downstream Manhole, Survey Begins - 1:35AM326.6 ft. MWL - Water Level, 10 %of cross sectional area326.6 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active326.6 ft. MWM - Water Mark, 30 %of cross sectional area

Observation photos (1)

  • General Observation - 9.5' VCP-PVCP

    274.5 ft. - General Observation - 9.5' VCP-PVCP

Observations (6)

DistanceCodeObservation
0AMH1:35AM
326.6AMH4:35AM
0MWL
0MGOConn. @ Mh, 3 O' Clock. Active
0MWM
274.5MGO9.5' VCP-PVCP

Properties (8)

custom_field_three
LINER GOOD COND.
custom_field_two
4
customer
LACSD
datetime
2022-01-03T01:27:39-08:00
documentation
MARTIN,OLIVER 111,CASTILLO
is_lateral_inspection
false
lining
PVCP-Folded/Reformed
year_laid
20030131