- Date
- 01/06/2022
- W/O
- 0932376
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z01172
- PipeID
- P25977
- Time
- 1:39 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H2072
- Sewer Name
- 02 DOUGLAS AVENUE RELOCATION TRUNK
- City
- LOS ANGLES
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 12
- Purpose
- Routine Assessment
- Project
- 20220106MDM_DOUGLAS_AVENUE_RELOCATION_TRUNK
- Material
- CIP
- Shape
- Circular
- Height
- 10 in.
- Upstream MH
- 02 1884
- Downstream MH
- 02 2436
- Dir. of Survey
- Downstream
- Length Surveyed
- 310.8 ft.
- Total Length
- 310.8 ft.
- Structural Index
- 3
- Structural Quick
- 3322
- Structural Rating
- 13
- O&M Index
- 2
- O&M Quick
- 3122
- O&M Rating
- 7
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 20
Pipe schematic from manhole 02 1884 to 02 2436 Observation photos (5)

2 ft. - Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 15% PIPE LOSS

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING OUTER SURFACE

8 ft. - Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: NO - 15% PIPE LOSS

24.9 ft. - Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: NO - 15% PIPE LOSS

43 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING OUTER SURFACE