Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 7, 2022, 09:47 AM
  • 01 0355_01 0354_172022_041655.mp4

Date
01/07/2022
W/O
0931893
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00215
PipeID
P00829
Time
1:47 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H2076
Sewer Name
01 NADEAU TRUNK, SECTS 2&1
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
06
Purpose
Capital Improvement Program Assesment
Project
20220107MDM_NADEAU_TRUNK_SECTS_2_1
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
01 0355
Downstream MH
01 0354
Dir. of Survey
Downstream
Length Surveyed
195.7 ft.
Total Length
195.7 ft.
Structural Index
2
Structural Quick
3425
Structural Rating
22
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
22
Pipe schematic from manhole 01 0355 to 01 0354
MH: 01 0355MH: 01 0354downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:25AM0 ft. MWM - Water Mark, 30 %of cross sectional area7 ft. FC - Fracture Circumferential, from 08 to 01 o'clock, within 8 inches of joint: YES - SLIGHT24.2 ft. FL - Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES - HAIRLINE24.2 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - SL37.7 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL47.8 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H53.1 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H72.3 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - SLIGHT FRACTURE WITH SLIGHT INSET82.8 ft. FC - Fracture Circumferential, from 10 to 03 o'clock, within 8 inches of joint: YES - SL179.2 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H195.7 ft. AMH - Downstream Manhole, Survey Ends - 4:45AM

Observation photos (1)

  • Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - SLIGHT FRACTURE WITH SLIGHT INSET

    72.3 ft. - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - SLIGHT FRACTURE WITH SLIGHT INSET

Observations (13)

DistanceCodeObservation
37.7FCSL
7FCSLIGHT
53.1FLH
82.8FCSL
195.7AMH4:45AM
179.2FLH
0MWL
0AMH4:25AM
72.3FCSLIGHT FRACTURE WITH SLIGHT INSET
0MWM
47.8FLH
24.2FLHAIRLINE
24.2FCSL

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2022-01-07T01:47:48-08:00
documentation
MARTIN,REVELES,CASTILLO
is_lateral_inspection