- Date
- 12/08/2021
- W/O
- 921632
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00432
- PipeID
- P05559
- Time
- 11:19 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9557
- Sewer Name
- 05 DISTRICT #5 MAIN RELIEF TRUNK
- City
- LAWNDALE
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 17
- Purpose
- Routine Assessment
- Project
- RFIR_WO_921632_TV05325_NOV2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 36 in.
- Width
- 42 in.
- Upstream MH
- 05 0345
- Downstream MH
- 05 0344
- Dir. of Survey
- Downstream
- Length Surveyed
- 492.4 ft.
- Total Length
- 492.4 ft.
- Structural Index
- 3
- Structural Quick
- 3S2S
- Structural Rating
- 490
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 490
Pipe schematic from manhole 05 0345 to 05 0344 Observation photos (2)

2.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start