Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 9, 2021, 10:55 AM
  • 02 1347_02 1290_11092021_030713.mp4

Date
11/09/2021
W/O
921735
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00277
PipeID
P04621
Time
2:55 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9529
Sewer Name
02 JANE STREET BRANCH TRUNK
City
COMMERCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_921735_TV02342_NOV2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
02 1347
Downstream MH
02 1290
Dir. of Survey
Downstream
Length Surveyed
372.9 ft.
Total Length
372.9 ft.
Structural Index
3
Structural Quick
3N00
Structural Rating
222
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
224
Pipe schematic from manhole 02 1347 to 02 1290
MH: 02 1347MH: 02 1290downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 13470 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area3.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start41.7 ft. TBB - Tap Break-In Abandoned, at 10 o'clock, -, within 8 inches of joint: NO, 6"158.5 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"372.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish372.9 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK372.9 ft. AMH - Downstream Manhole, Survey Ends - 02 1290

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Abandoned, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    41.7 ft. - Tap Break-In Abandoned, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    158.5 ft. - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

Observations (9)

DistanceCodeObservation
158.5TBC
0AMH02 1347
0MWM
3.2CM
41.7TBB
372.9MGOCONNECTION AT THE MH 9 OC'LOCK
372.9AMH02 1290
372.8CM
0MWL

Properties (7)

additional_info
630074110821202
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-11-09T02:55:06-08:00
documentation
PROPIPE
is_lateral_inspection
false