Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 10, 2021, 08:56 AM
  • 02 1362_02 1361_11102021_010811.mp4

Date
11/10/2021
W/O
921735
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00277
PipeID
P03885
Time
12:56 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9531
Sewer Name
02 JANE STREET BRANCH TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
11A
Purpose
Routine Assessment
Project
RFIR_WO_921735_TV02342_NOV2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
15 in.
Upstream MH
02 1362
Downstream MH
02 1361
Dir. of Survey
Downstream
Length Surveyed
270.4 ft.
Total Length
270.4 ft.
Structural Index
3
Structural Quick
3J00
Structural Rating
159
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
159
Pipe schematic from manhole 02 1362 to 02 1361
MH: 02 1362MH: 02 1361downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 13624.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"5.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start46.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"109.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"133.5 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"187.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"230 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"266 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"270.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish270.4 ft. AMH - Downstream Manhole, Survey Ends - 02 1361

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
270.4CM
46.2TF
230TF
266TF
0MWL
187.8TF
133.5TF
109.6TF
270.4AMH02 1361
5.8CM
0MWM
0AMH02 1362
4.3TF

Properties (7)

additional_info
630074110921202
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-11-10T00:56:35-08:00
documentation
PROPIPE
is_lateral_inspection
false