Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 5, 2021, 05:45 PM
  • 32 1282_32 1281_11052021_100317.mp4

Date
11/05/2021
W/O
916875
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00834
PipeID
P19747
Time
10:45 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9273
Sewer Name
32 DISTRICT #26 INTERCEPTOR TRUNK
City
SANTA CLARITA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
09
Purpose
Routine Assessment
Project
WO_916875_TV32031_OCT2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
36 in.
Width
36 in.
Upstream MH
32 1282
Downstream MH
32 1281
Dir. of Survey
Downstream
Length Surveyed
308.5 ft.
Total Length
308.5 ft.
Structural Index
2
Structural Quick
2K00
Structural Rating
122
O&M Index
2
O&M Quick
2K00
O&M Rating
122
Overall Index
2
Overall Quick
Overall Rating
244
Pipe schematic from manhole 32 1282 to 32 1281
MH: 32 1282MH: 32 1281downstream0 ft. AMH - Upstream Manhole, Survey Begins - 32 12820 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start100.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6"112.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN233.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN306 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish306.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish308.5 ft. AMH - Downstream Manhole, Survey Ends - 32 1281308.5 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
0AMH32 1282
233.7TFOPEN
308.5AMH32 1281
2.7DAGS
306.5DAGS
0MWL
0MWM
100.1TFA
308.5MGOCONN @ MH 9 O'CLOCK/ACTIVE
112.7TFOPEN
2SSS
306SSS

Properties (8)

additional_info
630074110521061
custom_field_three
SPALLING
custom_field_two
3
customer
1
datetime
2021-11-05T10:45:53-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
29654