Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 26, 2021, 10:23 AM
  • 32 1276_32 1275_10262021_023145.mp4

Date
10/26/2021
W/O
916875
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00834
PipeID
P20542
Time
3:23 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9472
Sewer Name
32 DISTRICT #26 INTERCEPTOR TRUNK
City
SANTA CLARITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
09
Purpose
Routine Assessment
Project
WO_916875_TV32031_OCT2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
32 1275
Downstream MH
32 1276
Dir. of Survey
Upstream
Length Surveyed
11.5 ft.
Total Length
11.5 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole 32 1275 to 32 1276
MH: 32 1275MH: 32 1276upstream0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish0 ft. MGO - General Observation - ROACHES @ MH0 ft. AMH - Upstream Manhole, Survey Ends - 32 12760 ft. MGO - General Observation - STOP LOG @ MOUTH OF PIPE.0 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish7.5 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start9.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start11.5 ft. MWL - Water Level, 25 %of cross sectional area11.5 ft. AMH - Downstream Manhole, Survey Begins - 32 127511.5 ft. MWM - Water Mark, 30 %of cross sectional area

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    4 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - ROACHES @ MH

    11.5 ft. - General Observation - ROACHES @ MH

  • General Observation - STOP LOG @ MOUTH OF PIPE.

    11.5 ft. - General Observation - STOP LOG @ MOUTH OF PIPE.

Observations (10)

DistanceCodeObservation
0MWL
11.5DAGS
11.5MGOROACHES @ MH
2DAGS
11.5AMH32 1276
11.5MGOSTOP LOG @ MOUTH OF PIPE.
11.5CM
4CM
0AMH32 1275
0MWM

Properties (8)

additional_info
630069102521201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-10-26T03:23:59-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
29654