Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 27, 2021, 08:05 AM
  • 32 1269_32 1268_10272021_001237.mp4

Date
10/27/2021
W/O
916875
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00834
PipeID
P19737
Time
1:05 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9473
Sewer Name
32 DISTRICT #26 INTERCEPTOR TRUNK
City
SANTA CLARITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
09
Purpose
Routine Assessment
Project
WO_916875_TV32031_OCT2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
33 in.
Width
33 in.
Upstream MH
32 1269
Downstream MH
32 1268
Dir. of Survey
Downstream
Length Surveyed
80.8 ft.
Total Length
80.8 ft.
Structural Index
2
Structural Quick
2B00
Structural Rating
30
O&M Index
2
O&M Quick
2E00
O&M Rating
62
Overall Index
2
Overall Quick
Overall Rating
92
Pipe schematic from manhole 32 1269 to 32 1268
MH: 32 1269MH: 32 1268downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 12690 ft. MWL - Water Level, 25 %of cross sectional area2 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start78 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish78 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish80 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Finish80 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE80 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE80.8 ft. AMH - Downstream Manhole, Survey Ends - 32 126880.8 ft. MGO - General Observation - ROACHES @ MH

Observation photos (3)

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - ROACHES @ MH

    80.8 ft. - General Observation - ROACHES @ MH

Observations (13)

DistanceCodeObservation
2DAE
78SSS
80DAE
2SSS
80.8AMH32 1268
0MWM
80MGOCONN @ MH 9 O'CLOCK/ACTIVE
78DAGS
80.8MGOROACHES @ MH
0AMH32 1269
80MGOCONN @ MH 3 O'CLOCK/ACTIVE
0MWL
2DAGS

Properties (7)

additional_info
630069102621201
custom_field_two
3
customer
1
datetime
2021-10-27T01:05:34-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
29654