Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 8, 2021, 11:26 AM
  • 02 2036A_02 1320_11082021_034241.mp4

Date
11/08/2021
W/O
921813
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00238
PipeID
P03841
Time
3:26 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9527
Sewer Name
02 BELVEDERE TRUNK
City
EAST LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_921813_TV02239_NOV2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
27 in.
Upstream MH
02 2036A
Downstream MH
02 1320
Dir. of Survey
Downstream
Length Surveyed
329.8 ft.
Total Length
329.8 ft.
Structural Index
3
Structural Quick
4133
Structural Rating
21
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
21
Pipe schematic from manhole 02 2036A to 02 1320
MH: 02 2036AMH: 02 1320downstream0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 2063A0 ft. MWL - Water Level, 0 %of cross sectional area24.1 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES65.1 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES90 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"109 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"130.1 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES133.1 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES152.6 ft. FS - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES188.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"199 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"246.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"300.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"317.4 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES320.4 ft. H - Hole, at 10 o'clock, within 8 inches of joint: NO329.8 ft. AOC - Drop Connection, Survey Ends - 02 1320

Observation photos (3)

  • Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES

    152.6 ft. - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    317.4 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Hole, at 10 o'clock, within 8 inches of joint: NO

    320.4 ft. - Hole, at 10 o'clock, within 8 inches of joint: NO

Observations (18)

DistanceCodeObservation
0MGOCONNECTION AT THE MH 3 OC'LOCK
90TF
133.1CL
152.6FS
300.6TFC
188.3TF
246.2TF
320.4H
0MWM
329.8AOC02 1320
109TF
199TF
317.4FM
0AMH02 2063A
130.1CL
24.1CL
65.1CL
0MWL

Properties (7)

additional_info
630074110821001
custom_field_three
multiple cracks/fracture
custom_field_two
2
customer
1
datetime
2021-11-08T03:26:29-08:00
documentation
PROPIPE
is_lateral_inspection
false