Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 4, 2021, 10:48 AM
  • 02 1316_02 1315_11042021_025629.mp4

Date
11/04/2021
W/O
921813
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00238
PipeID
P03836
Time
3:48 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9526
Sewer Name
02 BELVEDERE TRUNK
City
EAST LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_921813_TV02239_NOV2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
21 in.
Upstream MH
02 1316
Downstream MH
02 1315
Dir. of Survey
Downstream
Length Surveyed
151.7 ft.
Total Length
151.7 ft.
Structural Index
4
Structural Quick
4131
Structural Rating
7
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 02 1316 to 02 1315
MH: 02 1316MH: 02 1315downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 13160 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area11.1 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES20.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"22.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"25.9 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"27.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"30.5 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"42.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"83.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"114.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"147.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"151.6 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK151.7 ft. AMH - Downstream Manhole, Survey Ends - 02 1316

Observation photos (2)

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    25.9 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    30.5 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

Observations (15)

DistanceCodeObservation
83.3TFC
30.5TB
42.9TF
22.5TFC
0AMH02 1316
151.6MGOCONNECTION AT THE MH 9 OC'LOCK
0MWL
114.2TF
25.9TB
147.1TFC
20.3TFC
27.7TF
0MWM
151.7AMH02 1316
11.1FL

Properties (7)

additional_info
630074110321201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
3
customer
1
datetime
2021-11-04T03:48:14-07:00
documentation
PROPIPE
is_lateral_inspection
false