Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 8, 2021, 12:23 PM
  • 02 1309_02 1308_11082021_043930.mp4

Date
11/08/2021
W/O
921813
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00238
PipeID
P03829
Time
4:23 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9527
Sewer Name
02 BELVEDERE TRUNK
City
EAST LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_921813_TV02239_NOV2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
21 in.
Upstream MH
02 1308
Downstream MH
02 1309
Dir. of Survey
Upstream
Length Surveyed
327.3 ft.
Total Length
327.3 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 02 1308 to 02 1309
MH: 02 1308MH: 02 1309upstream0 ft. AMH - Upstream Manhole, Survey Ends - 02 13098.5 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"32.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"85.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"88.4 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"90.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"109.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"119 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"174.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"187.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"230.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"234.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"251.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"290.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"324.6 ft. CM - Crack Multiple, from 10 to 11 o'clock, within 8 inches of joint: YES327.3 ft. AMH - Downstream Manhole, Survey Begins - 02 1308327.3 ft. MWL - Water Level, 5 %of cross sectional area327.3 ft. MWM - Water Mark, 10 %of cross sectional area327.3 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK327.3 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK

Observation photos (2)

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    238.9 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    318.8 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

Observations (20)

DistanceCodeObservation
0AMH02 1308
139.8TF
0MWL
318.8TB
0MWM
93.2TF
37TFC
0MGOCONNECTION AT THE MH 9 OC'LOCK
152.7TF
76TFC
0MGOCONNECTION AT THE MH 3 OC'LOCK
2.7CM
327.3AMH02 1309
236.7TF
208.3TF
97TF
295.2TF
238.9TB
218.2TF
242TFC

Properties (7)

additional_info
630074110821001
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-11-08T04:23:33-08:00
documentation
PROPIPE
is_lateral_inspection
false