Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 4, 2021, 04:59 AM
  • 02 1931_02 1930_11032021_211102.mp4

Date
11/03/2021
W/O
921813
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00238
PipeID
P04704
Time
9:59 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9526
Sewer Name
02 BELVEDERE TRUNK
City
EAST LOS ANGELES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
05
Purpose
Routine Assessment
Project
RFIR_WO_921813_TV02239_NOV2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
24 in.
Upstream MH
02 1931
Downstream MH
02 1930
Dir. of Survey
Downstream
Length Surveyed
243.9 ft.
Total Length
243.9 ft.
Structural Index
4
Structural Quick
4431
Structural Rating
19
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
19
Pipe schematic from manhole 02 1931 to 02 1930
MH: 02 1931MH: 02 1930downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 19310 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area226.6 ft. FM - Fracture Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES231.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES236.6 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES238 ft. FM - Fracture Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES, Start242 ft. FM - Fracture Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES, Finish243.9 ft. AMH - Downstream Manhole, Survey Ends - 02 1930

Observation photos (3)

  • Fracture Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES

    226.6 ft. - Fracture Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    231.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    236.6 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

Observations (9)

DistanceCodeObservation
231.6FM
236.6FL
0AMH02 1931
242FM
243.9AMH02 1930
0MWL
0MWM
226.6FM
238FM

Properties (7)

additional_info
630074110321201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-11-03T21:59:59-07:00
documentation
PROPIPE
is_lateral_inspection
false