Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 4, 2021, 05:41 AM
  • 02 1927_02 1926_11032021_215540.mp4

Date
11/03/2021
W/O
921813
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00238
PipeID
P04275
Time
10:41 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9526
Sewer Name
02 BELVEDERE TRUNK
City
EAST LOS ANGELES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
05
Purpose
Routine Assessment
Project
RFIR_WO_921813_TV02239_NOV2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
18 in.
Upstream MH
02 1927
Downstream MH
02 1926
Dir. of Survey
Downstream
Length Surveyed
162.1 ft.
Total Length
162.1 ft.
Structural Index
4
Structural Quick
4E11
Structural Rating
129
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
129
Pipe schematic from manhole 02 1927 to 02 1926
MH: 02 1927MH: 02 1926downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 19273.9 ft. FM - Fracture Multiple, from 11 to 05 o'clock, within 8 inches of joint: YES8.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES16.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: NO18.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start130.1 ft. CC - Crack Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES162.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish162.1 ft. AMH - Downstream Manhole, Survey Ends - 02 1926

Observation photos (4)

  • Fracture Multiple, from 11 to 05 o'clock, within 8 inches of joint: YES

    3.9 ft. - Fracture Multiple, from 11 to 05 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    8.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: NO

    16.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: NO

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    18.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
3.9FM
18.3FM
16.2FM
0MWM
130.1CC
0MWL
0AMH02 1927
162.1FM
8.3FM
162.1AMH02 1926

Properties (7)

additional_info
630074110321201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-11-03T22:41:43-07:00
documentation
PROPIPE
is_lateral_inspection
false