Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 4, 2021, 08:15 AM
  • 02 1328_02 2042_11042021_003038.mp4

Date
11/04/2021
W/O
921813
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00238
PipeID
P03852
Time
1:15 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9526
Sewer Name
02 BELVEDERE TRUNK
City
EAST LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_921813_TV02239_NOV2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
27 in.
Upstream MH
02 1328
Downstream MH
02 2042
Dir. of Survey
Downstream
Length Surveyed
289 ft.
Total Length
289 ft.
Structural Index
3
Structural Quick
3K12
Structural Rating
176
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
176
Pipe schematic from manhole 02 1328 to 02 2042
MH: 02 1328MH: 02 2042downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 13280 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area3 ft. CM - Crack Multiple, from 09 to 11 o'clock, within 8 inches of joint: YES16.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"40.8 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"75.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"84.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"144.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"200 ft. CC - Crack Circumferential, from 10 to 01 o'clock, within 8 inches of joint: YES202.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"210.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"236.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"263 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"272.4 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"277 ft. CC - Crack Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES288.9 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK289 ft. AMH - Downstream Manhole, Survey Ends - 02 2042

Observation photos (2)

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    40.8 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    272.4 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

Observations (18)

DistanceCodeObservation
236.1TFC
277CC
288.9MGOCONNECTION AT THE MH 3 OC'LOCK
75.1TFC
3CM
202.4TF
272.4TB
16.4TF
0AMH02 1328
0MWM
144.6TFC
263TFC
40.8TB
200CC
289AMH02 2042
0MWL
84.3TFC
210.4TF

Properties (7)

additional_info
630074110321201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-11-04T01:15:38-07:00
documentation
PROPIPE
is_lateral_inspection
false