Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 9, 2021, 08:17 AM
  • 02 1299_02 1298_11092021_003707.mp4

Date
11/09/2021
W/O
921813
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00238
PipeID
P03816
Time
12:17 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9528
Sewer Name
02 BELVEDERE TRUNK
City
EAST LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_921813_TV02239_NOV2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
18 in.
Upstream MH
02 1299
Downstream MH
02 1298
Dir. of Survey
Downstream
Length Surveyed
381.3 ft.
Total Length
381.3 ft.
Structural Index
3
Structural Quick
3O24
Structural Rating
248
O&M Index
1
O&M Quick
1L00
O&M Rating
67
Overall Index
2
Overall Quick
Overall Rating
315
Pipe schematic from manhole 02 1299 to 02 1298
MH: 02 1299MH: 02 1298downstream0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. AMH - Upstream Manhole, Survey Begins - 02 12990 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area3.1 ft. CM - Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES37 ft. CC - Crack Circumferential, from 12 to 01 o'clock, within 8 inches of joint: YES63.1 ft. RFJ - Roots Fine Joint, at 09 o'clock, within 8 inches of joint: YESR66.1 ft. RFJ - Roots Fine Joint, from 04 to 05 o'clock, within 8 inches of joint: YESR74.1 ft. RFJ - Roots Fine Joint, from 08 to 09 o'clock, within 8 inches of joint: YESR79.9 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"81 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES83.3 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"85 ft. RFJ - Roots Fine Joint, from 04 to 05 o'clock, within 8 inches of joint: YESR - 5%103.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"107.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"133 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES134.3 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"139 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"144.1 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES148.1 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"173.1 ft. CC - Crack Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES183.4 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"183.4 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"185.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"188.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"216 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES219.5 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"221.5 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"231.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"261.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"267.6 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"269.1 ft. CC - Crack Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES272.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"297 ft. CM - Crack Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES305.9 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"308.9 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"309 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES315.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"351 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES351.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"381.3 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish381.3 ft. AMH - Downstream Manhole, Survey Ends - 02 1298381.3 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK381.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (14)

  • Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

    3.1 ft. - Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, at 09 o'clock, within 8 inches of joint: YESR

    63.1 ft. - Roots Fine Joint, at 09 o'clock, within 8 inches of joint: YESR

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    79.9 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    83.3 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    134.3 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    148.1 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    183.4 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    183.4 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    219.5 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    221.5 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    261.7 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    267.6 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    305.9 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    308.9 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

Observations (44)

DistanceCodeObservation
221.5TB
0MGOCONNECTION AT THE MH 3 OC'LOCK
381.3RFJ
0AMH02 1299
315.8TFC
308.9TB
351CL
83.3TB
351.1TFC
3.1CM
173.1CC
148.1TB
269.1CC
66.1RFJ
107.8TFC
81CL
188.9TFC
63.1RFJ
37CC
0MWL
309CM
0MWM
261.7TB
381.3AMH02 1298
183.4TB
79.9TB
74.1RFJ
219.5TB
183.4TB
133CL
85RFJ5%
134.3TB
231.4TFC
139TFC
144.1CL
381.3MGOCONNECTION AT THE MH 9 OC'LOCK
267.6TB
305.9TB
272.2TFC
103.6TFC
185.6TFC
381.3CM
216CM
297CM

Properties (7)

additional_info
630074110821201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-11-09T00:17:39-08:00
documentation
PROPIPE
is_lateral_inspection
false