Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 8, 2021, 10:52 AM
  • 02 1294_02 1293_11082021_030545.mp4

Date
11/08/2021
W/O
921813
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00238
PipeID
P03811
Time
2:52 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9527
Sewer Name
02 BELVEDERE TRUNK
City
EAST LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_921813_TV02239_NOV2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
18 in.
Upstream MH
02 1293
Downstream MH
02 1294
Dir. of Survey
Upstream
Length Surveyed
352.6 ft.
Total Length
352.6 ft.
Structural Index
2
Structural Quick
3221
Structural Rating
9
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
9
Pipe schematic from manhole 02 1293 to 02 1294
MH: 02 1293MH: 02 1294upstream0 ft. AMH - Upstream Manhole, Survey Ends - 02 129420.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"30.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"61.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"74.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"105 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"120.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"150.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"158.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"161.1 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"188.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"193.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"204.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"212.5 ft. CC - Crack Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES236.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"245.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"278.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"285.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"324.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"338.9 ft. CM - Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES344 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES352.6 ft. MWM - Water Mark, 20 %of cross sectional area352.6 ft. MWL - Water Level, 10 %of cross sectional area352.6 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK352.6 ft. AMH - Downstream Manhole, Survey Begins - 02 1293

Observation photos (2)

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    8.6 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    191.5 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

Observations (25)

DistanceCodeObservation
194.4TFC
0MWM
27.7TF
115.7TF
332.5TF
0MWL
158.9TF
164TF
8.6CL
0MGOCONNECTION AT THE MH 9 OC'LOCK
74.1TF
277.9TF
140.1CC
352.6AMH02 1294
247.6TF
148.2TF
291.3TF
322.3TF
107.3TF
202TF
13.7CM
67.5TFC
0AMH02 1293
191.5TB
232.2TF

Properties (7)

additional_info
630074110821001
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-11-08T02:52:16-08:00
documentation
PROPIPE
is_lateral_inspection
false