- Date
- 11/10/2021
- W/O
- 916517
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00174
- PipeID
- P10750
- Time
- 8:32 AM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9276
- Sewer Name
- H JOINT OUTFALL H - UNIT 3
- City
- PICO RIVERA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- RFIR_WO_916517_TV02323_OCT2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 57 in.
- Width
- 57 in.
- Upstream MH
- H 0294
- Downstream MH
- H 0295
- Dir. of Survey
- Upstream
- Length Surveyed
- 340.8 ft.
- Total Length
- 340.8 ft.
- Structural Index
- 5
- Structural Quick
- 5J3A
- Structural Rating
- 303
- O&M Index
- 2
- O&M Quick
- 2L00
- O&M Rating
- 128
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 431
Pipe schematic from manhole H 0294 to H 0295 Observation photos (3)

20.3 ft. - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - SLUDGE

71.2 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

288.3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start