Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 30, 2021, 06:30 PM
  • 29 0413_29 0410_09302021_121506.mp4

Date
09/30/2021
W/O
916408
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z01090
PipeID
P24450
Time
11:30 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9145
Sewer Name
29 ALAMITOS PUMPING PLANT SEWER
City
SIGNAL HILL
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_916408_TV29104_OCT2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0413
Downstream MH
29 0410
Dir. of Survey
Downstream
Length Surveyed
86.8 ft.
Total Length
86.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
4135
O&M Rating
22
Overall Index
3
Overall Quick
Overall Rating
22
Pipe schematic from manhole 29 0413 to 29 0410
MH: 29 0413MH: 29 0410downstream0 ft. AMH - Upstream Manhole, Survey Begins - 29 04130 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area6.1 ft. RML - Roots Medium Lateral, from 08 to 04 o'clock, 10 %, within 8 inches of joint: YES6.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"21.3 ft. RFB - Roots Fine Barrell, from 08 to 04 o'clock, Start47.1 ft. RML - Roots Medium Lateral, from 09 to 10 o'clock, 10 %, within 8 inches of joint: YES48.1 ft. RML - Roots Medium Lateral, from 08 to 04 o'clock, 15 %, within 8 inches of joint: YES48.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"48.9 ft. RMJ - Roots Medium Joint, from 08 to 04 o'clock, 15 %, within 8 inches of joint: YESR59.7 ft. RMB - Roots Medium Barrell, from 04 to 08 o'clock, 15 %, within 8 inches of joint: YES59.7 ft. RFB - Roots Fine Barrell, from 08 to 04 o'clock, Finish74.5 ft. RMJ - Roots Medium Joint, from 08 to 04 o'clock, 10 %, within 8 inches of joint: YESR84.8 ft. RFJ - Roots Fine Joint, from 08 to 01 o'clock, within 8 inches of joint: YES86 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"86.8 ft. MSA - Survey Abandoned - COMPLETED REVERSE

Observation photos (9)

  • Roots Medium Lateral, from 08 to 04 o'clock, 10 %, within 8 inches of joint: YES

    6.1 ft. - Roots Medium Lateral, from 08 to 04 o'clock, 10 %, within 8 inches of joint: YES

  • Roots Fine Barrell, from 08 to 04 o'clock, Start

    21.3 ft. - Roots Fine Barrell, from 08 to 04 o'clock, Start

  • Roots Medium Lateral, from 09 to 10 o'clock, 10 %, within 8 inches of joint: YES

    47.1 ft. - Roots Medium Lateral, from 09 to 10 o'clock, 10 %, within 8 inches of joint: YES

  • Roots Medium Lateral, from 08 to 04 o'clock, 15 %, within 8 inches of joint: YES

    48.1 ft. - Roots Medium Lateral, from 08 to 04 o'clock, 15 %, within 8 inches of joint: YES

  • Roots Medium Joint, from 08 to 04 o'clock, 15 %, within 8 inches of joint: YESR

    48.9 ft. - Roots Medium Joint, from 08 to 04 o'clock, 15 %, within 8 inches of joint: YESR

  • Roots Medium Barrell, from 04 to 08 o'clock, 15 %, within 8 inches of joint: YES

    59.7 ft. - Roots Medium Barrell, from 04 to 08 o'clock, 15 %, within 8 inches of joint: YES

  • Roots Medium Joint, from 08 to 04 o'clock, 10 %, within 8 inches of joint: YESR

    74.5 ft. - Roots Medium Joint, from 08 to 04 o'clock, 10 %, within 8 inches of joint: YESR

  • Roots Fine Joint, from 08 to 01 o'clock, within 8 inches of joint: YES

    84.8 ft. - Roots Fine Joint, from 08 to 01 o'clock, within 8 inches of joint: YES

  • Survey Abandoned - COMPLETED REVERSE

    86.8 ft. - Survey Abandoned - COMPLETED REVERSE

Observations (16)

DistanceCodeObservation
48.1RML
6.1RML
86.8MSACOMPLETED REVERSE
21.3RFB
48.1TF
84.8RFJ
47.1RML
0AMH29 0413
59.7RMB
6.1TF
0MWM
74.5RMJ
48.9RMJ
86TFC
0MWL
59.7RFB

Properties (6)

custom_field_three
PROTRUDING LATERAL
custom_field_two
3
customer
1
datetime
2021-09-30T11:30:03-07:00
documentation
PRO PIPE
is_lateral_inspection
false