Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 29, 2021, 03:06 PM
  • 29 0406_29 0405_09292021_083140.mp4

Date
09/29/2021
W/O
916408
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z01090
PipeID
P24443
Time
8:06 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9144
Sewer Name
29 ALAMITOS PUMPING PLANT SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_916408_TV29104_OCT2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0405
Downstream MH
29 0406
Dir. of Survey
Upstream
Length Surveyed
270.1 ft.
Total Length
270.1 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 29 0405 to 29 0406
MH: 29 0405MH: 29 0406upstream0 ft. CM - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish0 ft. ACOM - Cleanout Mainline, Survey Ends - 29 04062 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"7.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"25.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"27.4 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6"64.4 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6"72 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"92.2 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6"105.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"136.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"146.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"174.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"177.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"225.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"231.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"262.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"264 ft. CM - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start266 ft. CM - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES270.1 ft. MWL - Water Level, 5 %of cross sectional area270.1 ft. AMH - Downstream Manhole, Survey Begins - 29 0405270.1 ft. MWM - Water Mark, 20 %of cross sectional area

Observation photos (5)

  • Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

    4.1 ft. - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    6.1 ft. - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    177.9 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    205.7 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    242.7 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6"

Observations (22)

DistanceCodeObservation
0MWL
177.9TB
95.3TF
270.1CM
268.1TFC
44.5TF
244.5TF
262.4TFC
6.1CM
38.3TF
270.1ACOM29 0406
93TF
242.7TB
7.6TF
0AMH29 0405
4.1CM
134TF
198.1TF
205.7TB
0MWM
164.7TF
123.8TF

Properties (7)

additional_info
630138092921051
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-09-29T08:06:04-07:00
documentation
PRO PIPE
is_lateral_inspection
false