Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 25, 2021, 09:27 AM
  • 29 0397_29 0396_10252021_024029.mp4

Date
10/25/2021
W/O
916408
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01090
PipeID
P24434
Time
2:27 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9512
Sewer Name
29 ALAMITOS PUMPING PLANT SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
03
Purpose
Routine Assessment
Project
RFIR_WO_916408_TV29104_OCT2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0397
Downstream MH
29 0396
Dir. of Survey
Downstream
Length Surveyed
252.5 ft.
Total Length
252.5 ft.
Structural Index
4
Structural Quick
514H
Structural Rating
188
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
188
Pipe schematic from manhole 29 0397 to 29 0396
MH: 29 0397MH: 29 0396downstream0 ft. AMH - Upstream Manhole, Survey Begins - 29 03970 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 5 %of cross sectional area2.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES6.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start32.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start32.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish39.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"41.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"95.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"97.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"104 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"106.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"108.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"186.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"189.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"248.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"249.4 ft. B - Broken, from 02 to 05 o'clock, within 8 inches of joint: YES252.5 ft. AMH - Downstream Manhole, Survey Ends - 29 0396252.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (5)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    2.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    32.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    104 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Broken, from 02 to 05 o'clock, within 8 inches of joint: YES

    249.4 ft. - Broken, from 02 to 05 o'clock, within 8 inches of joint: YES

Observations (20)

DistanceCodeObservation
0AMH29 0397
248.2TFC
252.5AMH29 0396
32.3FM
41.8TFC
97.3TFC
252.5FM
249.4B
95.3TFC
189.2TF
39.1TF
0MWL
0MWM
6.1CM
32.3CM
2.3FM
186.4TF
108.6TF
106.3TF
104TB

Properties (7)

additional_info
630074102521003
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-10-25T02:27:29-07:00
documentation
PRO PIPE
is_lateral_inspection
false