22 1028_22 1027_11042021_105126.mp4
2.1 ft. - Roots Fine Joint, at 11 o'clock, within 8 inches of joint: NO - FROM MH
204.8 ft. - Roots Fine Joint, from 01 to 02 o'clock, within 8 inches of joint: YES
209.3 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES
237.8 ft. - Roots Fine Joint, from 04 to 05 o'clock, within 8 inches of joint: YES
238.2 ft. - Roots Medium Lateral, from 02 to 05 o'clock, 20 %, within 8 inches of joint: NO
238.6 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish
| Distance | Code | Observation |
|---|---|---|
| 238.8 | TF | — |
| 209.3 | CL | — |
| 238.2 | RML | — |
| 0 | MWM | — |
| 238.8 | MSA | UNABLE TO PASS ROOTS |
| 238.6 | DAGS | — |
| 237.8 | RFJ | — |
| 2.1 | RFJ | FROM MH |
| 0 | AMH | 22 1028 |
| 173.7 | TF | — |
| 2.1 | DAGS | — |
| 0 | MGO | ACTIVE CONNECTION AT THE MH 3 OC'LOCK |
| 108.8 | TFA | — |
| 0 | MWL | — |
| 39 | TFC | — |
| 204.8 | RFJ | — |
| 237.9 | DAGS | — |