Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 3, 2021, 06:35 AM
  • 02 1624_02 1623_11022021_225255.mp4

Date
11/02/2021
W/O
921736
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00235
PipeID
P04644
Time
11:35 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9522
Sewer Name
02 ATLANTIC AVENUE TRUNK
City
EAST LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_921736_TV02356_NOV2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
18 in.
Upstream MH
02 1624
Downstream MH
02 1623
Dir. of Survey
Downstream
Length Surveyed
317 ft.
Total Length
317 ft.
Structural Index
3
Structural Quick
4I3L
Structural Rating
400
O&M Index
2
O&M Quick
2L00
O&M Rating
126
Overall Index
3
Overall Quick
Overall Rating
526
Pipe schematic from manhole 02 1624 to 02 1623
MH: 02 1624MH: 02 1623downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 16240 ft. MWL - Water Level, 20 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start70 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start91.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN115.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN131 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start144 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish161.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6"239.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN291.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN306 ft. FS - Fracture Spiral, from 01 to 05 o'clock, within 8 inches of joint: YES315 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish315 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish317 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish317 ft. AMH - Downstream Manhole, Survey Ends - 02 1623317 ft. MGO - General Observation - ROACHES @ MH

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    70 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (19)

DistanceCodeObservation
315DAGS
131FM
317FM
2.1CM
91.1TFOPEN
306FS
0MWM
317AMH02 1623
0AMH02 1624
291.1TFOPEN
144FM
161.1TFA
239.7TFOPEN
317MGOROACHES @ MH
0MWL
2DAGS
70FM
315CM
115.4TFOPEN

Properties (7)

additional_info
630074110221202
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-11-02T23:35:04-07:00
documentation
PROPIPE
is_lateral_inspection
false