Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 7, 2021, 06:40 PM
Date
12/07/2021
W/O
0926416
Weather
Damp
Operator/Surveyor
FRANKLIN
Sewer ID
Z00594
PipeID
P12629
Time
10:40 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Jetting
Media Label
I0380
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 3&2A
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
01
Purpose
Maintenance Related
Project
ARCADIA_SIERRA_MADRE_TRUNK_SECTS_3_2A
Material
NRCP
Shape
Circular
Height
10 in.
Upstream MH
15 0851
Downstream MH
15 0850
Dir. of Survey
Downstream
Length Surveyed
352.4 ft.
Total Length
352.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2M00
O&M Rating
144
Overall Index
2
Overall Quick
Overall Rating
144
Pipe schematic from manhole 15 0851 to 15 0850
MH: 15 0851MH: 15 0850downstream0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 10:44 AM0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start36.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN85.8 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - 100% ROOTS-LATERAL/OPEN110.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN135 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN186.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"193.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"241.6 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4" - 100% ROOTS-LATERAL/OPEN350 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish352.4 ft. AMH - Downstream Manhole, Survey Ends - 11:13 AM352.4 ft. MGO - General Observation - CONN @MH 3 O'CLOCK/ACTIVE

Observations (16)

DistanceCodeObservation
110.3TFOPEN
85.8TFD100% ROOTS-LATERAL/OPEN
352.4AMH11:13 AM
36.8TFOPEN
352.4MGOCONN @MH 3 O'CLOCK/ACTIVE
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
350DAGS
2DAGS
0MWL
193.7TFA
135TFOPEN
241.6TFD100% ROOTS-LATERAL/OPEN
0MWM
186.7TFA
0AMH10:44 AM
0MGOCONN @ MH 3 O'CLOCK/ACTIVE

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2021-12-07T10:40:22-08:00
documentation
FRANKLIN, RAMIREZ, RUVALCABA
is_lateral_inspection
false