Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 18, 2021, 10:49 AM
  • 18 0794_18 0793_10182021_040002.mp4

Date
10/18/2021
W/O
916511
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00706
PipeID
P14652
Time
3:49 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9448
Sewer Name
18 SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
City
SANTA FE SPRINGS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
14
Purpose
Routine Assessment
Project
RFIR_WO_916511_TV18182_OCT2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
18 0793
Downstream MH
18 0794
Dir. of Survey
Upstream
Length Surveyed
56.8 ft.
Total Length
56.8 ft.
Structural Index
3
Structural Quick
3622
Structural Rating
22
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
22
Pipe schematic from manhole 18 0793 to 18 0794
MH: 18 0793MH: 18 0794upstream0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK CAPPED0 ft. AMH - Upstream Manhole, Survey Ends - 18 07940 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK CAPPED0.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES3.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish3.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES26 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start30.4 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES56.8 ft. MWM - Water Mark, 20 %of cross sectional area56.8 ft. MWL - Water Level, 10 %of cross sectional area56.8 ft. AMH - Downstream Manhole, Survey Begins - 18 0793

Observation photos (3)

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    26.4 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    30.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    53.3 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

Observations (11)

DistanceCodeObservation
56SSS
56.8MGOCONNECTION AT THE MH 3 OC'LOCK CAPPED
26.4CL
0MWM
56.8AMH18 0794
0MWL
53.3CM
30.8CM
53.3FL
0AMH18 0793
56.8MGOCONNECTION AT THE MH 9 OC'LOCK CAPPED

Properties (7)

additional_info
630074101821002
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2021-10-18T03:49:34-07:00
documentation
PROPIPE
is_lateral_inspection
false