Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 10, 2021, 04:34 PM
  • 01 0004_01 0003A_12102021_135853.mp4

Date
12/10/2021
W/O
0926256
Weather
Dry
Operator/Surveyor
IGNACIO
Sewer ID
PipeID
010003a-010004
Time
8:34 AM
Certificate
U-115-06022628
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H2045
Sewer Name
BULLIS ROAD LOCAL LINE
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
19
Purpose
Maintenance Related
Project
20211210MI_BULLIS_ROAD_LOCAL_LINE
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
01 0004
Downstream MH
01 0003A
Dir. of Survey
Downstream
Length Surveyed
314.1 ft.
Total Length
314.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 01 0004 to 01 0003A
MH: 01 0004MH: 01 0003Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 08:50 AM0 ft. MWL - Water Level, 0 %of cross sectional area - DRY LINE2 ft. MGO - General Observation - PIPE MATERIAL IS VCP7 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 4", 4" - OPEN45.7 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4" - OPEN84.6 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4" - OPEN123.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4" - OPEN169 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"211.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"250.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"292.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"314.1 ft. AMH - Downstream Manhole, Survey Ends - MH 0003A-BURIED

Observation photos (9)

  • Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 4", 4" - OPEN

    7 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 4", 4" - OPEN

  • Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4" - OPEN

    45.7 ft. - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4" - OPEN

  • Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4" - OPEN

    84.6 ft. - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4" - OPEN

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4" - OPEN

    123.6 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4" - OPEN

  • Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"

    169 ft. - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"

    211.3 ft. - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"

    250.1 ft. - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"

    292.7 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"

  • Downstream Manhole, Survey Ends - MH 0003A-BURIED

    314.1 ft. - Downstream Manhole, Survey Ends - MH 0003A-BURIED

Observations (12)

DistanceCodeObservation
250.1TFA
169TFA
314.1AMHMH 0003A-BURIED
292.7TF
45.7TFOPEN
2MGOPIPE MATERIAL IS VCP
7TFDOPEN
0AMH08:50 AM
123.6TFOPEN
211.3TFA
0MWLDRY LINE
84.6TFOPEN

Properties (7)

additional_info
TO CONFIRM PIPE MATERIAL AND LOCATIONS OF HOUSE CONNECTIONS
custom_field_three
TO CONFIRM PIPE MATERIAL/LOCATION OF CONNECTIONS
custom_field_two
5
customer
LACSD
datetime
2021-12-10T08:34:57-08:00
documentation
IGNACIO, SHADLER, RAMIREZ
is_lateral_inspection
false