Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 1, 2021, 11:11 AM
  • H 0628_H 0627A_11012021_035923.mp4

Date
11/01/2021
W/O
916544
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00183
PipeID
P27093
Time
4:11 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9479
Sewer Name
H JOINT OUTFALL H - UNIT 7B
City
CITY OF INDUSTRY
Loc. details
Main Highway - Urban
Location Code
A
District
District 15
Page No.
38
Purpose
Routine Assessment
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Other
Height
39 in.
Upstream MH
H 0628
Downstream MH
H 0627A
Dir. of Survey
Downstream
Length Surveyed
330.8 ft.
Total Length
330.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole H 0628 to H 0627A
MH: H 0628MH: H 0627Adownstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 06280 ft. MWL - Water Level, 10 %of cross sectional area2 ft. MLC - Lining Change, Cured in place268.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"330.8 ft. AMH - Downstream Manhole, Survey Ends - H 0627A

Observation photos (1)

  • Lining Change, Cured in place

    2 ft. - Lining Change, Cured in place

Observations (6)

DistanceCodeObservation
0MWM
2MLC
330.8AMHH 0627A
0AMHH 0628
0MWL
268.7TFA

Properties (7)

additional_info
630069110121002
custom_field_three
RFIR/LINED
custom_field_two
3
customer
1
datetime
2021-11-01T04:11:07-07:00
documentation
PRO PIPE
is_lateral_inspection
false