Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 13, 2021, 11:24 AM
  • 05 0114_05 0113_12132021_043404.mp4

Date
12/13/2021
W/O
0926975
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00431
PipeID
P05404
Time
3:24 AM
Certificate
U-1014-06922543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H2048
Sewer Name
05 DISTRICT #5 MAIN TRUNK
City
HAWTHORNE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
10
Purpose
Capital Improvement Program Assesment
Project
20211213MDM_DISTRICT_5_MAIN_TRUNK
Material
Reinforced Concrete Pipe
Shape
Circular
Height
39 in.
Upstream MH
05 0114
Downstream MH
05 0113
Dir. of Survey
Downstream
Length Surveyed
333.9 ft.
Total Length
333.9 ft.
Structural Index
3
Structural Quick
3222
Structural Rating
10
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole 05 0114 to 05 0113
MH: 05 0114MH: 05 0113downstream0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. OPEN0 ft. AMH - Upstream Manhole, Survey Begins - 4:30AM2 ft. MGO - General Observation - 98% MAG COAT START2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE18 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG118.7 ft. MGO - General Observation - 99% MAG COAT142.3 ft. SAP - Surface Aggregate Projecting, from 09 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG169.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE333.3 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. OPEN333.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG333.3 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active333.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE333.9 ft. AMH - Downstream Manhole, Survey Ends - 5:00AM

Observation photos (6)

  • General Observation - 98% MAG COAT START

    2 ft. - General Observation - 98% MAG COAT START

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    18 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • General Observation - 99% MAG COAT

    118.7 ft. - General Observation - 99% MAG COAT

  • Surface Aggregate Projecting, from 09 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG

    142.3 ft. - Surface Aggregate Projecting, from 09 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE

    169.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE

Observations (13)

DistanceCodeObservation
333.3MGOConn. @ Mh, 9 O' Clock. OPEN
333.3SAPSEVERE AGG
18SAPSEVERE AGG
0MGOConn. @ Mh, 9 O' Clock. OPEN
333.3MGOConn. @ Mh, 3 O' Clock. Active
2MGO98% MAG COAT START
142.3SAPSEVERE AGG
333.9AMH5:00AM
2SSSBLISTERING PEELING CONCRETE
169.3SSSPEELING CONCRETE
0AMH4:30AM
333.3SSSBLISTERING PEELING CONCRETE
118.7MGO99% MAG COAT

Properties (6)

custom_field_three
SEVERE AGG PROJECTING
custom_field_two
2
customer
LACSD
datetime
2021-12-13T03:24:15-08:00
documentation
MARTIN,REVELES,OLIVER 111.CASTILLO
is_lateral_inspection
false