- Date
- 12/13/2021
- W/O
- 0926975
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00431
- PipeID
- P21196
- Time
- 1:20 AM
- Certificate
- U-1014-06922543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H2048
- Sewer Name
- 05 DISTRICT #5 MAIN TRUNK
- City
- LENNOX
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 10
- Purpose
- Capital Improvement Program Assesment
- Project
- 20211213MDM_DISTRICT_5_MAIN_TRUNK
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 30 in.
- Upstream MH
- 05 2424
- Downstream MH
- 05 2445
- Dir. of Survey
- Downstream
- Length Surveyed
- 9.9 ft.
- Total Length
- 9.9 ft.
- Structural Index
- 3
- Structural Quick
- 3221
- Structural Rating
- 8
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 8
Pipe schematic from manhole 05 2424 to 05 2445 Observation photos (4)

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CPNCRETE

2 ft. - General Observation - MAG COAT 30% START

2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG

8 ft. - Surface Aggregate Projecting, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG