- Date
- 10/11/2021
- W/O
- 916508
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00659
- PipeID
- P13623
- Time
- 10:03 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9438
- Sewer Name
- 16 LAMANDA PARK TRUNK
- City
- PASADENA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 11
- Purpose
- Routine Assessment
- Project
- WO_916508_TV16077_OCT2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 22 in.
- Width
- 22 in.
- Upstream MH
- 16 0572
- Downstream MH
- 16 0571
- Dir. of Survey
- Downstream
- Length Surveyed
- 254.6 ft.
- Total Length
- 254.6 ft.
- Structural Index
- 3
- Structural Quick
- 5I3I
- Structural Rating
- 498
- O&M Index
- 2
- O&M Quick
- 2F11
- O&M Rating
- 71
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 569
Pipe schematic from manhole 16 0572 to 16 0571 Observation photos (4)

2.7 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

3 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

8.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

78.6 ft. - Roots Fine Barrell, from 09 to 03 o'clock, Start