Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 1, 2021, 04:29 PM
  • 08 0476_08 0475_12012021_105730.mp4

Date
12/01/2021
W/O
916502
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00025
PipeID
P00533
Time
8:29 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9287
Sewer Name
08 216TH STREET RELOCATION TRUNK
City
CARSON
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_916502_TV08101_OCT2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Width
12 in.
Upstream MH
08 0476
Downstream MH
08 0475
Dir. of Survey
Downstream
Length Surveyed
726.6 ft.
Total Length
726.6 ft.
Structural Index
3
Structural Quick
5\3\
Structural Rating
1445
O&M Index
2
O&M Quick
4131
O&M Rating
179
Overall Index
3
Overall Quick
Overall Rating
1624
Pipe schematic from manhole 08 0476 to 08 0475
MH: 08 0476MH: 08 0475downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 04760 ft. MWL - Water Level, 50 %of cross sectional area0 ft. MWM - Water Mark, 55 %of cross sectional area2 ft. MGO - General Observation - 35% MAG COAT2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start2 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start - HANGING DEPOSITS2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start5.9 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start9.5 ft. DAR - Deposits Attached Ragging, 10 %of cross sectional area, from 12 to 01 o'clock, , within 8 inches of joint: YES311.4 ft. DAZ - Deposits Attached Other, 15 %of cross sectional area, from 09 to 12 o'clock, , within 8 inches of joint: YES - HANGING PIPE MATERIAL725.8 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish725.8 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish725.8 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish725.8 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Finish - HANGING726.6 ft. AMH - Downstream Manhole, Survey Ends - 08 0475

Observation photos (6)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Deposits Settled Other,  5 %of cross sectional area, from 09 to 03 o'clock,  , within 8 inches of joint: YES, Start - HANGING DEPOSITS

    2 ft. - Deposits Settled Other, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start - HANGING DEPOSITS

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    5.9 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Ragging, 10 %of cross sectional area, from 12 to 01 o'clock,  , within 8 inches of joint: YES

    9.5 ft. - Deposits Attached Ragging, 10 %of cross sectional area, from 12 to 01 o'clock, , within 8 inches of joint: YES

  • Deposits Attached Other, 15 %of cross sectional area, from 09 to 12 o'clock,  , within 8 inches of joint: YES - HANGING PIPE MATERIAL

    311.4 ft. - Deposits Attached Other, 15 %of cross sectional area, from 09 to 12 o'clock, , within 8 inches of joint: YES - HANGING PIPE MATERIAL

Observations (15)

DistanceCodeObservation
725.8SAP
311.4DAZHANGING PIPE MATERIAL
725.8SRC
2MGO35% MAG COAT
9.5DAR
5.9SRC
0AMH08 0476
726.6AMH08 0475
725.8SSS
2SAP
0MWL
2DSZHANGING DEPOSITS
2SSS
725.8DSZHANGING
0MWM

Properties (7)

additional_info
630098120121061
custom_field_three
REINFORCEMENT CORRODED
custom_field_two
1
customer
1
datetime
2021-12-01T08:29:18-08:00
documentation
PROPIPE
is_lateral_inspection
false