- Date
- 11/08/2021
- W/O
- 916502
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00025
- PipeID
- P00532
- Time
- 8:05 AM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9274
- Sewer Name
- 08 216TH STREET RELOCATION TRUNK
- City
- CARSON
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 13
- Purpose
- Routine Assessment
- Project
- RFIR_WO_916502_TV08101_OCT2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 48 in.
- Width
- 12 in.
- Upstream MH
- 08 0475
- Downstream MH
- 08 0474
- Dir. of Survey
- Downstream
- Length Surveyed
- 814.7 ft.
- Total Length
- 814.7 ft.
- Structural Index
- 3
- Structural Quick
- 5`3_
- Structural Rating
- 1625
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 1629
Pipe schematic from manhole 08 0475 to 08 0474 Observation photos (4)

2 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

59 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Change